Monday, October 31, 2011
Sunday, October 30, 2011
冷氣相關
冷媒填充 :
http://tw.myblog.yahoo.com/hungpont-younghong/article?mid=1073&sc=1
http://tw.myblog.yahoo.com/hungpont-younghong/archive?l=f&id=9
http://tw.myblog.yahoo.com/hungpont-younghong/article?mid=3799&prev=3874&next=3798&l=f&fid=9
http://www.mobile01.com/topicdetail.php?f=168&t=1237491&p=1
http://zhidao.baidu.com/question/50424931.html
http://cforum3.cari.com.my/search.php?searchid=5463&orderby=lastpost&ascdesc=desc&searchsubmit=yes
http://www.mobile01.com/topicdetail.php?f=335&t=725986&p=1
http://goods.ruten.com.tw/item/qa?11090912126204#qna
http://forum.u-car.com.tw/thread.asp?forumid=189100
http://www.youtube.com/watch?NR=1&v=KCGpX2ru2Xc
http://tw.myblog.yahoo.com/jw!y2eh_6uBHwQMt0PtQwXhe9pGlQ--/article?mid=81&prev=84&l=f&fid=9
http://www.youtube.com/watch?v=FNeWPPRH2E8&feature=related
http://club.pchome.com.tw/NBook/www/NBook_Read.php?No=37243&club_e_name=valy&view=1
安裝分離式冷氣較複雜首先你要準備以下工具:
1、 電鑽(室內機背板安裝用 )。
2、 螺絲字起.鉗子 .膠布 .板手( 配結線及安裝用)。
3、 擴管器(冷媒管配接用 )。
4、 真空泵浦(抽真空用也可排空方式不需抽真空但不建議 )。
5、 壓力錶組、冷煤一桶(添加用如果為新機安裝銅管 7m內可無需添加,請參閱說明書,但仍需壓力錶組,因冷媒不足不冷,冷煤太多也不冷)。
6、 銅管、排水軟 管、2mm 電線。
安裝方式:
1、背板鑚孔安裝固定, 若有既設排水管物低於排水管。
2、銅管擴管銜接至室內機背後。
3、配結線(室內機供電與室外機供電不同請參考室內 / 外機內有配線圖)。
4、將室內機掛上(各牌型式不同)。
5、室外機固定安裝後一樣配接銅管及電源。
* 注意擴管不正確易造成洩漏,配電不正確也易造成短路。
抽真空及灌冷媒:
抽真空:
1、首先,必須要有一桶冷媒。然後準備一付高低壓量表, 紅圓表為高壓,如果你只要抽真空那你就不管它 了,另一個就是低壓表, 而有三個接管,中間為共同管 路,(在高壓表下的管為高壓 管,同理在低壓表下的管為低壓管 )。
2、所以你要把低壓表下那個管路連接在低壓管工作頭上 (即分離式較粗的那個銅管旁有個2 分工作頭) 在把表中間那個(共同管路 )接到抽真空機上就可以開始抽了 (記得高壓表那個開關要鎖緊, 而低壓表的開關要全打開)下。
3、抽的時間以管路和內機大小而定, 如不放心可抽20~30分鐘或分後抽先抽 10分鐘在抽 10分鐘然後關閉低壓表開關 (準備站壓) 。
4、當你抽完時低壓表中的指針要一直卡在真空下 (即低壓表下一般數字30 的,綠字那, 如有跑回去表示你冷氣銅管某部分有外漏現象) 另一說法就是你抽真空時低壓表會往下走, 反正走到卡住就是真空如有回就是有外漏。
5、當抽完真空最少讓它站壓一下( 即卡真空) 如都沒回那恭喜你,準備六角板 手,先打開高壓就是那個較細的銅管旁有個六角開關( 這時你看低壓表壓力會一直跑到表底) 這時你可以打開低壓表開關一點點讓冷媒漏個5 秒馬上關起來,再來就是打開低壓就是較粗的銅管旁一樣有個六角開關, 當你高低壓六角開關都都開好了那你準備開冷氣試機了,當壓縮機起動時你會發現壓力表會往回走 (那是正常 )當走到一定的時間 5~15分鐘不等冷媒因該在低壓表外圍數字 60~70, 如不足那去借冷媒來充吧。
6、若沒有真空泵浦採排氣方法先不將低壓閥的管路上緊,將高壓閥冷媒放出約 15sec,此時冷媒會從低壓閥未上緊處跑掉,順便將管內的空氣一並帶走。 15sec後再將低壓閥鎖緊即可, 若不放心可延長排放時間。
灌冷媒:
1、 先打開冷氣機,讓冷氣運轉。注意,如果沒有開冷氣的話,壓縮機冷媒的壓力很高,冷媒灌不進去。也比較危險,接管的時候,容易噴出太多冷媒。
2、 拆開冷氣機的螺帽2分工作頭(大頭的低壓管那一邊)接上藍色低壓管子,即可判讀壓 力,中間黃色管接冷煤桶 ,連接工作頭時也應排空軟管內空氣再行鎖緊。
3、 關閉低壓表開關,表上的壓力讀數,就是壓縮機中冷媒的壓力度數。(冷氣運轉中,這個壓力度數應該在60 ~70 PSI之間)
4、 壓力表如果小於 70PSI,則打開關閉低壓表開關,讓冷媒灌入壓縮機。
這時打開旋鈕開關的狀況,可見壓力指針一下子上升了許多。
注意:這時候冷媒正在流動,壓力很高,但不是壓縮機的冷媒度數。
灌個幾秒鐘,再把關閉低壓表開關。讀取壓縮機的冷媒壓力。
注意:不要太貪心,開關開太久,一下子灌太多冷媒。最好是灌個幾秒鐘,就關閉開關,重新檢查壓縮機的壓力。如果還不夠的話,打開開關再灌一些。讓壓縮機的冷媒壓力在 60~ 70 PSI 之間即可。 接著關閉冷媒桶的開關。關閉低壓表的開關。然後再把低壓管移除。
注意:這時候會露出一點冷媒,沒有關係。壓力不會差多少。
以上希望對您有幫助
將室內機內的冷煤回流到室外機:
1 、其實真的不建議你自己更換,因工具不夠( 重新拉管需有切管刀及擴管工貝、回收需六角板手,另最後需真空泵抽真空) 。
2 、如果你還是要自己動手,以下的步驟提供你參考。
3、 先將冷媒回收至室外機側─將室內機切至冷氣模式,運轉五分鐘後將高壓閥關掉 (較小那個 ),等約 30sec~1min後將低壓閥關掉,再關掉室內機。若管路不長冷媒於 30sec內可回收完,若你沒壓力錶可看,用聽的也可大約聽出。就是壓縮機抽不到東西的感覺。
4、 後更換你的管路,這時需有切管刀及擴管工具。要鎖上時不可太緊,用手上緊後再用活動板手上緊二分之一圈。
5、 管路安裝完後,需對管路抽真空或排空的動作,若你有真空泵抽真空是最好的,若沒有先不將低壓閥的管路上緊 ,將高壓閥冷媒放出約15sec,此時冷媒會從低壓閥未上緊處跑掉,順便將管內的空氣一並帶走。 15sec後再將低壓閥鎖緊即可。
6、 此時即可將高低壓閥打開,再度使用冷氣了,這時因你的冷媒被放掉了一些,故若室內溫度真的無法降低時就需再補充冷媒了。至於補冷媒,簡單一點可依額定電流、回流管結露情形或室內機吹出溫度來判斷。
7、 再次和你說一下,不成功的安裝是會減低空調機組的使用壽命的,望你三思。
http://tw.myblog.yahoo.com/hungpont-younghong/article?mid=1073&sc=1
http://tw.myblog.yahoo.com/hungpont-younghong/archive?l=f&id=9
http://tw.myblog.yahoo.com/hungpont-younghong/article?mid=3799&prev=3874&next=3798&l=f&fid=9
http://www.mobile01.com/topicdetail.php?f=168&t=1237491&p=1
http://zhidao.baidu.com/question/50424931.html
http://cforum3.cari.com.my/search.php?searchid=5463&orderby=lastpost&ascdesc=desc&searchsubmit=yes
http://www.mobile01.com/topicdetail.php?f=335&t=725986&p=1
http://goods.ruten.com.tw/item/qa?11090912126204#qna
http://forum.u-car.com.tw/thread.asp?forumid=189100
http://www.youtube.com/watch?NR=1&v=KCGpX2ru2Xc
http://tw.myblog.yahoo.com/jw!y2eh_6uBHwQMt0PtQwXhe9pGlQ--/article?mid=81&prev=84&l=f&fid=9
http://www.youtube.com/watch?v=FNeWPPRH2E8&feature=related
http://club.pchome.com.tw/NBook/www/NBook_Read.php?No=37243&club_e_name=valy&view=1
安裝分離式冷氣較複雜首先你要準備以下工具:
1、 電鑽(室內機背板安裝用 )。
2、 螺絲字起.鉗子 .膠布 .板手( 配結線及安裝用)。
3、 擴管器(冷媒管配接用 )。
4、 真空泵浦(抽真空用也可排空方式不需抽真空但不建議 )。
5、 壓力錶組、冷煤一桶(添加用如果為新機安裝銅管 7m內可無需添加,請參閱說明書,但仍需壓力錶組,因冷媒不足不冷,冷煤太多也不冷)。
6、 銅管、排水軟 管、2mm 電線。
安裝方式:
1、背板鑚孔安裝固定, 若有既設排水管物低於排水管。
2、銅管擴管銜接至室內機背後。
3、配結線(室內機供電與室外機供電不同請參考室內 / 外機內有配線圖)。
4、將室內機掛上(各牌型式不同)。
5、室外機固定安裝後一樣配接銅管及電源。
* 注意擴管不正確易造成洩漏,配電不正確也易造成短路。
抽真空及灌冷媒:
抽真空:
1、首先,必須要有一桶冷媒。然後準備一付高低壓量表, 紅圓表為高壓,如果你只要抽真空那你就不管它 了,另一個就是低壓表, 而有三個接管,中間為共同管 路,(在高壓表下的管為高壓 管,同理在低壓表下的管為低壓管 )。
2、所以你要把低壓表下那個管路連接在低壓管工作頭上 (即分離式較粗的那個銅管旁有個2 分工作頭) 在把表中間那個(共同管路 )接到抽真空機上就可以開始抽了 (記得高壓表那個開關要鎖緊, 而低壓表的開關要全打開)下。
3、抽的時間以管路和內機大小而定, 如不放心可抽20~30分鐘或分後抽先抽 10分鐘在抽 10分鐘然後關閉低壓表開關 (準備站壓) 。
4、當你抽完時低壓表中的指針要一直卡在真空下 (即低壓表下一般數字30 的,綠字那, 如有跑回去表示你冷氣銅管某部分有外漏現象) 另一說法就是你抽真空時低壓表會往下走, 反正走到卡住就是真空如有回就是有外漏。
5、當抽完真空最少讓它站壓一下( 即卡真空) 如都沒回那恭喜你,準備六角板 手,先打開高壓就是那個較細的銅管旁有個六角開關( 這時你看低壓表壓力會一直跑到表底) 這時你可以打開低壓表開關一點點讓冷媒漏個5 秒馬上關起來,再來就是打開低壓就是較粗的銅管旁一樣有個六角開關, 當你高低壓六角開關都都開好了那你準備開冷氣試機了,當壓縮機起動時你會發現壓力表會往回走 (那是正常 )當走到一定的時間 5~15分鐘不等冷媒因該在低壓表外圍數字 60~70, 如不足那去借冷媒來充吧。
6、若沒有真空泵浦採排氣方法先不將低壓閥的管路上緊,將高壓閥冷媒放出約 15sec,此時冷媒會從低壓閥未上緊處跑掉,順便將管內的空氣一並帶走。 15sec後再將低壓閥鎖緊即可, 若不放心可延長排放時間。
灌冷媒:
1、 先打開冷氣機,讓冷氣運轉。注意,如果沒有開冷氣的話,壓縮機冷媒的壓力很高,冷媒灌不進去。也比較危險,接管的時候,容易噴出太多冷媒。
2、 拆開冷氣機的螺帽2分工作頭(大頭的低壓管那一邊)接上藍色低壓管子,即可判讀壓 力,中間黃色管接冷煤桶 ,連接工作頭時也應排空軟管內空氣再行鎖緊。
3、 關閉低壓表開關,表上的壓力讀數,就是壓縮機中冷媒的壓力度數。(冷氣運轉中,這個壓力度數應該在60 ~70 PSI之間)
4、 壓力表如果小於 70PSI,則打開關閉低壓表開關,讓冷媒灌入壓縮機。
這時打開旋鈕開關的狀況,可見壓力指針一下子上升了許多。
注意:這時候冷媒正在流動,壓力很高,但不是壓縮機的冷媒度數。
灌個幾秒鐘,再把關閉低壓表開關。讀取壓縮機的冷媒壓力。
注意:不要太貪心,開關開太久,一下子灌太多冷媒。最好是灌個幾秒鐘,就關閉開關,重新檢查壓縮機的壓力。如果還不夠的話,打開開關再灌一些。讓壓縮機的冷媒壓力在 60~ 70 PSI 之間即可。 接著關閉冷媒桶的開關。關閉低壓表的開關。然後再把低壓管移除。
注意:這時候會露出一點冷媒,沒有關係。壓力不會差多少。
以上希望對您有幫助
將室內機內的冷煤回流到室外機:
1 、其實真的不建議你自己更換,因工具不夠( 重新拉管需有切管刀及擴管工貝、回收需六角板手,另最後需真空泵抽真空) 。
2 、如果你還是要自己動手,以下的步驟提供你參考。
3、 先將冷媒回收至室外機側─將室內機切至冷氣模式,運轉五分鐘後將高壓閥關掉 (較小那個 ),等約 30sec~1min後將低壓閥關掉,再關掉室內機。若管路不長冷媒於 30sec內可回收完,若你沒壓力錶可看,用聽的也可大約聽出。就是壓縮機抽不到東西的感覺。
4、 後更換你的管路,這時需有切管刀及擴管工具。要鎖上時不可太緊,用手上緊後再用活動板手上緊二分之一圈。
5、 管路安裝完後,需對管路抽真空或排空的動作,若你有真空泵抽真空是最好的,若沒有先不將低壓閥的管路上緊 ,將高壓閥冷媒放出約15sec,此時冷媒會從低壓閥未上緊處跑掉,順便將管內的空氣一並帶走。 15sec後再將低壓閥鎖緊即可。
6、 此時即可將高低壓閥打開,再度使用冷氣了,這時因你的冷媒被放掉了一些,故若室內溫度真的無法降低時就需再補充冷媒了。至於補冷媒,簡單一點可依額定電流、回流管結露情形或室內機吹出溫度來判斷。
7、 再次和你說一下,不成功的安裝是會減低空調機組的使用壽命的,望你三思。
Saturday, October 15, 2011
GPS MFM-PPG
每次找不到最新地圖的連結, 舊的放在Archieve中
新的先到MFM的facebook, 會在那公布最新的release, copy and google it, will get the URL
新的先到MFM的facebook, 會在那公布最新的release, copy and google it, will get the URL
Subscribe to: